Plant Growth ChambersPlant Growth Chambers

Plant Growth Chamber Lab Companion
Plant growth chamber with capacity up to 1000L for all your plant growth needs. User-friendly programmable logic microprocessor, and streamlined design optimizes air flow and temperature uniformity.
Temperature Range (C/F): 5-50 / 41-122
Humidity Range (RH %): 40-90
Price: Call Us For A Quote!

Overview

Operation Overview
• 5℃ to 50℃ (lamp off) / 10℃ to 50℃ (lamp on)
• Max. to 35,000Lux for GC-1000TLH
  Max. to 20,000Lux for GC-300 series
• 50 to 90% RH (only for TLH series)
• 300 to 5,000ppm CO2 control (optional)
• Microprocess PID control/ Auto-tuning/ Calibration
• Digital timer: 1 min to 99 hr 59 min
• Over-temperature limiter/ Door opening alarm
• 10 temperature, humidity, and illumination programmable settings, repeatable up to 999 cycles (self-testing)

Design Overview
• High quality 304 stainless steel interior and dirt-repellent power coated exterior
• User-friendly door system
  - Silicone packing to maintain inner chamber conditions
  - External door with magnetic sealing for dual airtight
  - Opens smoothly to minimize damage against test samples
• Wide inner tempered glass doors provide a full view of the sample
  - A tempered window provides a clear view of your specimen during testing
• Powerful air circulator for exclusive air-flow
  - Very efficient with spreading type air-flow system for plant growth
  - One propeller for GC-1000TLH/ A tangent blower and a sirocco fan for GC-300 series
• High frequency electronic ballast lamps
  - Reinforced Blue and Red spectrums lighting system for plant photosynthesis
  - Economical efficiency with stable light and long life span
  - Convenient exchange of lamps
• Minimization of rising heat
  - Unique construction to minimize rising heat due to a luminous source
  - Designed to exhaust heat through upper holes (only for GC-1000TLH)
• Easy cleaning of condenser air-filter
  - To prevent deterioration of refrigerator, easy and periodic cleaning of dust from filter
• Easy transport and installation
• Electronic humidity sensor supports easy calibration and fast reaction
• Dual type water level sensor/ Adjustable water tank positions (only for GC-300TLH)
• Separable shelf and rounded inner chamber corners for easy cleaning

Safety functions
• Leakage breaker for power supply
• Over current protector
• Overheat protectors
• Switch-off after alarm for over heating
• Water empty (TLH models only)
• Door opening alarm

Specifications

Model GC-300TL GC-300TLH GC-1000TLH
Chamber volume(L/cu ft) 300 / 10.6 1000 / 35.3
Controller Microprocessor PID controller
Temperature Range(℃/℉) 5 to 50 / 41 to 122 - Lamp off
10 to 50 / 50 to 122 - Lamp on
20 to 50 / 68 to 122 - with humidity
Fluctuation(±℃/℉)
at 25℃
0.1 / 0.18 - without humidity
Variation(±℃/℉)
at 25℃
0.8 / 1.43 - without humidity
Illumination Range(Lux) 0 to 20,000 0 to 35,000
Control(steps) 10 11
Lamp FL lamp (32W X 18EA) FL lamp (32W X 16EA)
Metal lamp (400W X 3EA)
Humidity Range(RH %)
-
40~80 at 20~35℃ 50~90 at 20~35℃
70~90 at 36~50℃ 50~90 at 36~50℃
Fluctuation(±RH)
at 60% RH
-
3
CO2(Optional) Range(ppm) 300 to 5,000
Sensor NDIR CO2 sensor
Refrigeration(HP) 1/2 3/4
Temp. heater power(W) 750 X 2EA 1,500 X 2EA
Humid. heater power(W) - 1300 1500
Dimensions
(WxDxH)
Interior(mm/inch) 510x540x1100 / 20.0x21.3x43.3 1200x800x1080
/ 47.2x31.5x42.5
Exterior(mm/inch) 700x765x1900 / 27.6x30.1x74.8 1410x1070x2150
/ 55.5x42.1x84.7
Net weight (kg/lbs) 250 / 551.2 550 / 1212.5
Electrical Requirements
(230V)
60Hz/ 12.5A 50Hz/ 12.5A 60Hz/ 16.0A 50Hz/ 16.0A 60Hz/ 30A 50Hz/ 30A
Cat. NO. AAHA1011 AAHA1012 AAHA1021 AAHA1022 AAHA1031 AAHA1032

For more information, please call us at (888) 538-8715 or contact us.

Plant Growth Chambers

Plant Growth Chamber Lab Companion
Plant growth chamber with capacity up to 1000L for all your plant growth needs. User-friendly programmable logic microprocessor, and streamlined design optimizes air flow and temperature uniformity.
Temperature Range (C/F): 5-50 / 41-122
Humidity Range (RH %): 40-90
Price: Call Us For A Quote!

Overview

Operation Overview
• 5℃ to 50℃ (lamp off) / 10℃ to 50℃ (lamp on)
• Max. to 35,000Lux for GC-1000TLH
  Max. to 20,000Lux for GC-300 series
• 50 to 90% RH (only for TLH series)
• 300 to 5,000ppm CO2 control (optional)
• Microprocess PID control/ Auto-tuning/ Calibration
• Digital timer: 1 min to 99 hr 59 min
• Over-temperature limiter/ Door opening alarm
• 10 temperature, humidity, and illumination programmable settings, repeatable up to 999 cycles (self-testing)

Design Overview
• High quality 304 stainless steel interior and dirt-repellent power coated exterior
• User-friendly door system
  - Silicone packing to maintain inner chamber conditions
  - External door with magnetic sealing for dual airtight
  - Opens smoothly to minimize damage against test samples
• Wide inner tempered glass doors provide a full view of the sample
  - A tempered window provides a clear view of your specimen during testing
• Powerful air circulator for exclusive air-flow
  - Very efficient with spreading type air-flow system for plant growth
  - One propeller for GC-1000TLH/ A tangent blower and a sirocco fan for GC-300 series
• High frequency electronic ballast lamps
  - Reinforced Blue and Red spectrums lighting system for plant photosynthesis
  - Economical efficiency with stable light and long life span
  - Convenient exchange of lamps
• Minimization of rising heat
  - Unique construction to minimize rising heat due to a luminous source
  - Designed to exhaust heat through upper holes (only for GC-1000TLH)
• Easy cleaning of condenser air-filter
  - To prevent deterioration of refrigerator, easy and periodic cleaning of dust from filter
• Easy transport and installation
• Electronic humidity sensor supports easy calibration and fast reaction
• Dual type water level sensor/ Adjustable water tank positions (only for GC-300TLH)
• Separable shelf and rounded inner chamber corners for easy cleaning

Safety functions
• Leakage breaker for power supply
• Over current protector
• Overheat protectors
• Switch-off after alarm for over heating
• Water empty (TLH models only)
• Door opening alarm

Specifications

Model GC-300TL GC-300TLH GC-1000TLH
Chamber volume(L/cu ft) 300 / 10.6 1000 / 35.3
Controller Microprocessor PID controller
Temperature Range(℃/℉) 5 to 50 / 41 to 122 - Lamp off
10 to 50 / 50 to 122 - Lamp on
20 to 50 / 68 to 122 - with humidity
Fluctuation(±℃/℉)
at 25℃
0.1 / 0.18 - without humidity
Variation(±℃/℉)
at 25℃
0.8 / 1.43 - without humidity
Illumination Range(Lux) 0 to 20,000 0 to 35,000
Control(steps) 10 11
Lamp FL lamp (32W X 18EA) FL lamp (32W X 16EA)
Metal lamp (400W X 3EA)
Humidity Range(RH %)
-
40~80 at 20~35℃ 50~90 at 20~35℃
70~90 at 36~50℃ 50~90 at 36~50℃
Fluctuation(±RH)
at 60% RH
-
3
CO2(Optional) Range(ppm) 300 to 5,000
Sensor NDIR CO2 sensor
Refrigeration(HP) 1/2 3/4
Temp. heater power(W) 750 X 2EA 1,500 X 2EA
Humid. heater power(W) - 1300 1500
Dimensions
(WxDxH)
Interior(mm/inch) 510x540x1100 / 20.0x21.3x43.3 1200x800x1080
/ 47.2x31.5x42.5
Exterior(mm/inch) 700x765x1900 / 27.6x30.1x74.8 1410x1070x2150
/ 55.5x42.1x84.7
Net weight (kg/lbs) 250 / 551.2 550 / 1212.5
Electrical Requirements
(230V)
60Hz/ 12.5A 50Hz/ 12.5A 60Hz/ 16.0A 50Hz/ 16.0A 60Hz/ 30A 50Hz/ 30A
Cat. NO. AAHA1011 AAHA1012 AAHA1021 AAHA1022 AAHA1031 AAHA1032

For more information, please call us at (888) 538-8715 or contact us.